Samsung AJ100FCJ5EH Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Climatiseurs à système divisé Samsung AJ100FCJ5EH. Samsung Multi Sistema - Un. Exterior - AJ100FCJ5EH/EU Guia de Instalação Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - Air Conditioner

Air Conditionerinstallation manualimagine the possibilitiesThank you for purchasing this Samsung product. RJ100F5HX**AJ100FCJ5**

Page 2 - Safety precautions

10ARJ100F5HX** / AJ100FCJ5**Follow dierent orders depending on the capacity of indoor units.**016/020/023/026/030/035**/AQV07/09/12**/AR07/09/12**

Page 3

11ENGLISHChecking gas leakageBefore completing the installation (insulation of the cables, hose and piping and xing of the indoor unit to the install

Page 4 - Accessories

12ACharging additional refrigerantIf you install the excessive length of pipe, add additional refrigerant as 20g per unit meter ;refer to the table be

Page 5

13AENGLISHMethod for connecting wiresSpecification for circuit breaker and power supply cord䭭 Power supply cord is not supplied with air conditioner.

Page 6

14 Carbon plastic Steel corePVC-insulated green/yellow wire, 2mm² x 3.5 mTo earthing screw50 cm30 cm1.Select an earthing electrode

Page 7 - Fixing the unit in position

15AENGLISHSetting indoor unit address automaticallySetting indoor unit address ◆ Switch the system on and wait for code " " to appear on t

Page 8 - ◆ Piping outside diameter

16AStep 1 Review all the following elements in the installation:◆ Installation site strength◆ Piping connection tightness to detect any gas leakage◆

Page 9

17ENGLISHROTARY SWITCH “SW02” POSITION ACCORDING TO REFRIGERANT CIRCUIT CONNECTED ( 0=A; 1=B; 2=C; 3=D; 4=E )Indoor UnitSW020Att. "A"1Att.

Page 10 - Refrigerant piping work

18AHigh Temp Button High Fan ButtonMode changeLow Temp Button Low Fan ButtonEntering mode for setting optionOption setting modeX Setting option 1. R

Page 11 - Checking gas leakage

19ENGLISHOperation Indication * Step 11. Remove the batteries from the remote controller. 2. Insert batteries while pressing High Temp Button and Low

Page 12 - Method for connecting wires

2ContentsSafety precautions(Carefully follow the precautions listed below because they are essential to guarantee the safety of the equipment.)WARNING

Page 13

20A1. Check whether power is supplied or not. - When the indoor unit is not plugged in, there should be additional power supply in the indoor unit

Page 14

21ENGLISHt 8IFOi"w_w'wJTFOUFSFEUP4&(_UIFJOEPPSVOJU."*/"%%3&44JTOPUDIBOHFEt *GZPVTFUUIF4&(

Page 15 - Setting indoor unit address

22AAmpere Limit Setting & Changing ProcedureAmpere 3WITCH3ELECTIONRJ100F5HX**AJ100FCJ5**Switch 3 423A(OFF)On On20A(OFF)On Off18A(OFF)Off On16A(OF

Page 16

23ENGLISHSettings of PCB Display of the Outdoor unit◆ Key Options of PCB Display - K1 : pipe checking operation button - K2 : Function

Page 17 - IT'S HERE!

24AInstalling transmitter and sub PCB for central control◆ RJ100F5HX** / AJ100FCJ5**Accessories (Transmitter : MIM-B13B)1. Turn the power off and take

Page 18

25ENGLISH1. Turn the power o and take o the front panel of the indoor unit.2. Take o the PCB cover.3. Attach the Sub PCB to the right side of th

Page 19

26A1. Check whether power is supplied or not. - When the indoor unit is not plugged in, there should be additional power supply in the indoor

Page 20

27AENGLISHTest run and nal checkTest RunFinal Check and Explaining operation to the owner1. Please do cool mode try-run or heat mode try-run. ◆ Coo

Page 21

28ATroubleshooting◆ The error indicated on the PCB display of outdoor unit%*41-":&91-"/"5*0/5IFFSSPSJOEJDBUFEPOUIF1$#EJTQMB

Page 22 - Setting installation option

29ENGLISH%*41-": &91-"/"5*0/5IFFSSPSJOEJDBUFEPOUIF1$#EJTQMBZPGPVUEPPSVOJU 3&."3,EvaOut1 Sensor Short/OpenEvaOu

Page 23

3ENGLISHSafety precautionsGENERAL INFORMATIONX Do not attempt to repair, move, alter or reinstall the unit. If performed by unauthorized personnel, t

Page 24 - / AJ100FCJ5

30AHow to connect your extended power cables1. Prepare the following tools.Tools Crimping pliersConnection sleeve (mm)Insulation tape Contraction tub

Page 25

31ENGLISH5. Wrap it with the insulation tape twice or more and position your contraction tube in the middle of the insulation tape. Three or more lay

Page 27 - Test run and nal check

4ADeciding on where to install the air conditionerGeneralWhen deciding on the location of the air conditioner with the owner, the following restrictio

Page 28 - ATroubleshooting

5ENGLISH ◆ You have just purchased a Free Joint Multi air conditioner and it has been installed by your installation specialist. ◆ This device must

Page 29

6ASpace requirement for outdoor unitWhen installing 1 outdoor unit300 or more※ When the air outlet is opposite the wall1500 or more※ When the air

Page 30 - Troubleshooting

7ENGLISH1.Position the outdoor unit so that the air flow is directed towards the outside, as indicated by the arrows on the top of the unit.2.Attach t

Page 31

8A◆ Piping length and the height◆ Piping outside diameter ❋ The appearance of the unit may be dierent from the diagram depending on the model.Main

Page 32 - DB68-04599A-07

9AENGLISH1. Make sure that you have the required tools available (pipe cutter, reamer,aring tool and pipe holder).2. If you wish to shorten the pip