Samsung AS123BBDN Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Climatiseurs à système divisé Samsung AS123BBDN. Samsung AS185EWDN User manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 40
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
AS12TC Series
AS18TC Series
AS18ED Series
AS24ED Series
DB98-32985A(2)
Air Conditioner
user & installation manual
imagine the possibilities
Thank you for purchasing this Samsung product.
To receive more complete service, please
register your product at
www.samsung.com/register
E
AS12BGC Series
AS18BGC Series
AS24BGC Series
AS12BBD Series
AS18BBD Series
AS24BBD Series
Boracay_AS12B_SPI@_IBIM_32985A_E.indd 43 2010-12-13 �� 10:00:57
Vue de la page 0
1 2 3 4 5 6 ... 39 40

Résumé du contenu

Page 1 - Air Conditioner

AS12TC SeriesAS18TC SeriesAS18ED SeriesAS24ED Series DB98-32985A(2)Air Conditioneruser & installation manualimagine the possibilitiesThank

Page 2 - Safety precautions

10Basic operation is an operation mode that can be selected by pressing the Mode button. AutoIn Auto mode, the air conditioner will automatically set

Page 3

11Press the button to turn on the air conditioner.Press the button to set the operating mode.• Each time you press the Mode button, the mode will

Page 4 - Safety precautions

12Bio Sleep mode Adjusting the air ow directionAir ow can be directed to your desired position.Turbo function will be helpful to cool your room qui

Page 5 - FOR CLEANING

13Bio Sleep modeFor a comfortable sleep, the air conditioner will operate it Fall asleep  Sound sleep  Wake up from mode.1. Press the Bio Sleep

Page 6 - Checking before use

14Setting the On/O timerYou can set the air conditioner to turn on/o automatically at desired time. Setting On timer while the air conditioner is o

Page 7

15Combining On Timer and O TimerIf the air conditioner is on If the air conditioner is oPreset time on On timer is longer than O timerEx) On timer

Page 8 - Remote controller buttons

16Using the Auto Clean functionYou can reduce the noise generated from an indoor unit. Press the Quiet button on the remote controller while the air

Page 9 - Remote controller display

17Using the Auto Clean functionAuto clean function will prevent from growing mold by eliminating the moisture inside of the indoor unit. Your indoor u

Page 10 - Basic function

18Cleaning the air conditionerCleaning the indoor unitCleaning the outdoor unit heat exchangerOpening the panel Wipe the surface of the unit with a

Page 11

19Removing the Air lterGrab the handle and lift it up. Then, pull the Air lter towards you and slide it down. Air lterCleaning the air lterWashabl

Page 12 - Using the Turbo function

2Safety precautions ... 23Choosing the installation location ...

Page 13

20Maintaining the air conditionerIf the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain it in bes

Page 14 - Setting the On/O timer

21TroubleshootingRefer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary expenses.PROBLEM SOLUTION

Page 15 - BBD models)

22 TroubleshootingPROBLEM SOLUTIONError is indicated. • When an indoor unit indicator blinks, contact the nearest service center.Noise is generated

Page 16 - Using the Quiet function

23Carefully follow the precautions listed below because they are essential to guarantee the safety of the equipment.• Always disconnect the air condi

Page 17

24Installing the unitIMPORTANT: When installing the unit, always remember to connect rst the refrigerant tubes, then the electrical lines. Always d

Page 18 - Cleaning the air conditioner

25Outdoor Unit Where it is not exposed to strong wind Well ventilated and dustless places Out of the direct sunlight and rainWhere neighbors a

Page 19 - Cleaning the air lter

26Space Requirements for Outdoor UnitWhen installing 1 outdoor unitWhen installing more than 1 outdoor unit300 or more When the air outlet is opposi

Page 20 - Troubleshooting

27(Unit : mm) When the upper part of the outdoor unit and the air outlet is opposite the wall When the walls are blocking front and the rear side

Page 21

28Tools required for installationGeneral Tools• Vacuum Pump(Backward owing prevention) • Manifold Gauge • Stud Finder • Torque Wrench • Pipe Cutte

Page 22 - Troubleshooting

291. Extend the assembly cable if necessary.• Do not connect two or more dierent cables to extend the length. It may cause re. When you instal

Page 23

3Safety precautionsBefore using your new air conditioner, please read this manual thoroughly to ensure that you know how to safely and eciently opera

Page 24

30Connecting the assembly cable9. Connect the cables to the terminals as seen in the picture.• Each wire is labeled with the corresponding terminal

Page 25 - Outdoor Unit

31Installing and connecting the assembly pipe of the indoor unit1. Cut out the appropriate knock-out piece (A, B, C) on the rear of the indoor unit u

Page 26 - Accessories

32 Purging the indoor unit1. Unscrew the caps at the end of each pipe.   All inert gas exhausts from the indoor unit. 1. Make sure that you h

Page 27

33Outer Diameter Torque (kgf•cm)ø6.35 mm 140~170ø9.52 mm 250~280ø12.70 mm 380~420ø15.88 mm 440~480ø19.05 mm 990~1210ø22.23 mm 990~1210Indoor outlet pi

Page 28 - Connecting the assembly cable

34• The hose will be xed permanently into position after nishing the installation and the gas leak test; refer to page 36~37 for further details.

Page 29

35The outdoor unit is loaded with sucient R22 refrigerant. Do not vent R22 into atmosphere: it is a uorinated greenhouse gas. You should purge the

Page 30

36 AA• The remaining air in the Refrigeration cycle, which contains moisture, may cause malfunction on the compressor.• Always contact the serv

Page 31

37 AAFixing the indoor unit in placeInsulationPipes'X' mmRubber leg'Y' mmPerform the following work on the area where gas leak

Page 32 - Cutting or extending the pipe

38Final Check and Trial OperationTo complete the installation, perform the following checks and tests to ensure that the air conditioner operates corr

Page 33 - Flare nut

39How to connect your extended power cables Items to prepare (compressor and insulation tape should be prepared by an installation technician.)1.

Page 34 - Drain pan outlet

4 Safety precautionsFOR POWER SUPPLYWARNINGPlug the power plug into the wall socket in the right direction so that the cord runs towards the oor.

Page 35 - Purging the connected pipes

42QUESTIONS OR COMMENTS?COUNTRY CALL OR VISIT US ONLINE AT INDIA3030 82821800 1100111800 3000 8282www.samsung.comBoracay_AS12B_SPI@_IBIM_32985A_E.in

Page 36 - Performing the gas leak tests

5FOR USINGWARNINGIf any foreign substance such as water has entered the appliance, cut the power by unplugging the power plug and turning the circuit

Page 37

6Operation rangesThe table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the table for eci

Page 38

7Main partsDisplayS-Plasma ion indicatorOperation indicatorPower buttonTimer indicatorYour air conditioner may slightly look dierent from illustrat

Page 39

8 Checking the remote controllerRemote controller buttons• Point the remote controller towards the remote controller receiver of the indoor unit.•

Page 40 - QUESTIONS OR COMMENTS?

9Remote controller display• The signal may not be received well of electronic lighting style uorescent lamps such as inverter uorescent lamps are

Commentaires sur ces manuels

Pas de commentaire