INSTALLATION AND EXTERNAL CONNECTION
Output Connection
- To connect the power supply unit
Connect the DC+12V to the red line.
Connect GND to the black line.
- To connect the door lock device
Connect the plus(+) line of the lock device to DC+12V.
Connect the minus(-) line of the lock device to the white line.
- To connect the alarm device
Connect the plus(+) line of the alarm device to DC+12V.
Connect the minus(-) line of the alarm device to the purple line.
- To specify the lock type
POWER FAIL SAFE: Connect the yellow line to GND.
POWER FAIL SECURE: Leave the yellow line in the fl oating state.