- 15 -
6. PROTOCOL ID : 10
1) Maker :
ERNA HALF
2)DipSwitch:
Set 5,6,7,8 pin of SW501.(Protocol Select)
ON
OFF
SW501
12
34 5 6 78
SW501 1~2 : RS-485 termination (Refer to SCC-641/643 User's Manual)
3~4 : Only 2400 BPS.
3) Function
ernitec controller SCC-641/643
1
※₁
#(1~128)
→
CAM Camera Address Select
1 Pan/Tilt/Zoom/Focus/Iris Pan/Tilt/Zoom/Focus/Iris
2#(1~120)
→
Prepos Go to Preset (1 ~ 120)
3#(1~120)
→
ESC
→
Prepos Save Preset (1 ~ 120)
4AUTO
→
Sequence Auto Pan Start/Stop
5 Sequence Scan Start/Stop
6121
→
Prepos Pattern 1
7122
→
Prepos Pattern 2
8123
→
Prepos Pattern 3
9124
→
Prepos
※₂
10 125
→
Prepos Camera Reset
10 '?' (Text On) Camera Menu
11 'Palm' button Menu Mode : Enter Key
12 Joystick Up Menu Mode: '
↑
'Key
13 Joystick Down Menu Mode: '
↓
'Key
14 Joystick Left Menu Mode: '
←
'Key
15 Joystick Right Menu Mode: '
→
'Key
16 'clock' button Alarm Reset
※₁
ADDRESS SET : (SSC-641/643 ADDRESS +1).
※₂
It is used to select 'SIZE' and 'POSITION' in Setup Menu.
( **MAIN MENU **
→
CAMERA...
→
MOTION DET ON
→
AREA USER... or
**MAIN MENU **
→
VIDEO SET...
→
IRIS ALC...
→
AREA USER... )