ENGLISHOWNER’S INSTRUCTIONS & INSTALLATION MANUALMANUAL DE INSTRUCCIONES &MANUAL DE INSTALACIÓNMANUEL D’UTILISATION &MANUEL D’INSTALLATION
Selecting the Automatic Operating ModeYou can start the air conditioner in Automatic mode from your remotecontrol. In the Automatic mode, the standard
Cooling Your Room1If necessary, press the (On/Off) button.Result:◆The 5 Way indicator on the indoor unit lights up.◆ The air conditioner starts
Changing the Room Temperature QuicklyThe Turbo cooling function is used to cool your room as quickly as possible.EEEExxxxaaaammmmpppplllleeee : You
Removing Excess HumidityE-13ENGLISHIf the atmosphere in your room is very humid or damp, you canremove excess humidity without lowering the room tempe
Airing Your RoomIf the atmosphere in your room is stale, you can air the room usingthe Fan feature.1 If necessary, press the (On/Off) button.Res
Adjusting the Air Flow Direction VerticallyE-15ENGLISHDepending on the position of the indoor unit on the wall of your room,you can adjust the positio
Setting the On TimerIf you want to turn on the air conditioner before the timer reachesthe setting time, press the (ON/OFF) button. NNNNoooottttee
Setting the Off TimerThe Off Timer enables you to switch off the air conditioner automaticallyafter a given period of time. You can set the period of
Setting the Sleep TimerThe Sleep Timer can be used when you are cooling your room toswitch the air conditioner off automatically after a period of six
Operating RecommendationsHere are a few recommendations that you should follow when usingyour air conditioner.Topic RecommendationPower failure If a p
Safety PrecautionsThe following safety precautions must be taken when using your air conditioner.1 Make sure that the indoor unit is correctly ventila
Temperature and Humidity RangesThe following table indicates the temperature and humidity rangeswithin which the air conditioner can be used.If the ai
Cleaning Your Air ConditionerE-21ENGLISHTo get the best possible use out of your air conditioner, you mustclean it regularly to remove the dust that a
Solving Common ProblemsE-22Explanation/Solution◆ Check that the breaker used for the air conditioner is switched on.◆ Check that the 5 Way indicator o
Installing a Filter (Option)E-23ENGLISH3 Open the front grille by pulling on the tabs on the lower right and leftsides of the indoor unit.2 Insert the
Technical SpecificationsE-24✳ Standard rating conditions CoolingIndoorDB8026.7°F°CWB6719.4DB9535.0WB7523.9Outdoor10.0 10.0MODELPerformanceRatingsC
E-25ENGLISH10.0MODELPerformanceRatingsCapacity CoolingSEERMoisture RemovalAir FLOW(Cooling, HIGH)Sound Rating-OutdoorBtu/hPts/hCFMdBElectricalDataThe
E-26INSTALLATIONMANUAL
E-27ENGLISHContents◆PREPARING THEINSTALLATION Deciding on Where to Install the Air Conditioner . . . . . . . . . . . 28 Air Conditioner and Access
E-28Deciding on Where to Install the Air ConditionerWhen deciding on the location of the air conditioner with the owner, the following restrictionsmus
E-29ENGLISHPREPARING THE INSTALLATIONAB160 mm(6 inch)or more25 mm (1 inch) or moreRespect the clearances and maximum lengths indicated in the diagram
Contents◆PREPARING YOUR AIR CONDITIONER Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 View of the Unit
E-30PREPARING THE INSTALLATIONDeciding on Where to Install the Air Conditioner (cont.)Respect the clearances and maximum lengths indicated in the diag
E-31ENGLISHPREPARING THE INSTALLATIONPiping length and the height.A-unitB-unitC-unitPipe sizeUnitLiquid1/4"1/4"1/4"GAS1/2"3/8"
E-32Air Conditioner and AccessoriesThe following accessories are supplied with the air conditioner.➢ The quantities are indicated in parentheses.Acces
E-33ENGLISHFixing the Installation Plate30mm(1 )31665mm0Pipe Hole(2)916(10)252(11)275(5 )14012(3 )9058(2 )6038(1 )30316410~73016~182834()Before fixing
E-34PREPARING THE INSTALLATIONPurging the UnitOn delivery, the indoor unit is loaded with an inert gas. All this gasmust therefore be purged before co
E-35ENGLISHINSTALLING THE INDOOR UNITConnecting the Assembly CableThe outdoor unit is powered from the indoor unit via the assembly cable. If the outd
E-36Connecting the Assembly Cable (cont.)INSTALLING THE INDOOR UNIT1 2 E31A1A2A3E2 E35 Detach the control box from the indoor unit.9 Reinstall the con
E-37ENGLISHInstalling and Connecting the Indoor Unit Drain HoseINSTALLING THE INDOOR UNITCare must be taken when installing the drain hose for the ind
E-38Installing and Connecting the Indoor Unit Assembly PipingINSTALLING THE INDOOR UNITThere are two refrigerant pipes of different diameters:◆ A smal
E-39ENGLISHCutting/Extending the PipingINSTALLING THE INDOOR UNIT5 metres(16ft. 5in) of piping is supplied with the airconditioner(Optional). This len
View of the Unit The design and shape are subject to change according to the model.Indoor UnitAir filter(under the grille)Air flow blades (outlet)Air
E-40INSTALLING THE INDOOR UNITConnecting the Cables to the Outdoor Unit (cont.)One electric cable must be connected to the outdoor unit:◆ The assembly
E-41ENGLISHINSTALLING THE OUTDOOR UNITEA BC312L1L22A3 B31 2 3 1 21 31 2 3 21 2 31 32E EE3E E E1 21 2E3A BEL2 L1B3B2B1A3A2A11 2 EE31233 EEarth terminal
E-42INSTALLING THE OUTDOOR UNITAuxiliary Circuit BreakerElectrical Work1 The supply voltage must be the same as the rated voltage of the air condition
E-43ENGLISHINSTALLING THE OUTDOOR UNITChecking Correct EarthingIf the power distribution circuit does not have an earth or the earthdoes not comply wi
E-44Fixing the Unit in PositionThe outdoor unit must be installed on a rigid and stable base to avoid any increasein the noise level and vibration, pa
E-45ENGLISHConnecting Up and Purging the CircuitCOMPLETING THE INSTALLATIONABCDOutdoor unit Indoor unitGas pipe sideLiquid pipe sideThe outdoor unit i
E-46Performing Leak TestsBefore completing the installation (insulation of the cables, hose andpiping and fixing of the indoor unit to the installatio
E-47ENGLISHOnce you have checked that there are no leaks in the system, you can insulatethe piping, hose and cables and place the indoor unit on the i
E-48Checking and Testing OperationsCOMPLETING THEINSTALLATIONTo complete the installation, perform the following checks and teststo ensure that the ai
E-49ENGLISHExplaining Operations to the OwnerBefore leaving the premises on which you have installed the air conditioner,you should explain the follow
E-5ENGLISHAir Inlet(Rear)Air OutletConnection ValveOutdoor UnitUM18B1C2Outdoor UnitUM26B1C2Outdoor UnitUM27B1C3Air Inlet(Rear)Air Inlet(Rear)Air Outle
ELECTRONICSPrinted in KoreaTHIS AIR CONDITIONER IS MANUFACTURED BY:ESTE AIRE ACONDICIONADO HA SIDO FABRICADO POR:CE CLIMATISEUR EST FABRIQUE PAR:
Remote Control - Buttons and DisplayOperating mode( AUTO, COOL,DRY, FAN)Remote control transmission indicatorMode selection button(AUTO
Getting StartedYou have just purchased a split type air conditioner and it has been installed by your installation specialist.Your Owner’s Instruction
Inserting the Remote Control BatteriesPush the battery cover on the rear of the remote control with your thumbin the direction of the arrow and remove
5 Way Function Press the (ON/OFF) button one time and then select the desiredmode.1To stop the operating, press the (ON/OFF) button unti
Commentaires sur ces manuels