Samsung AS07A1AE Spécifications

Naviguer en ligne ou télécharger Spécifications pour Climatiseurs à système divisé Samsung AS07A1AE. Samsung AS07A1AE Product specifications Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 47
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
SERVICE
Manual
CONTENTSAIR CONDITIONER
1. Pre c a u t i o n s
2. Product Specifications
3. Operating Instructions and
I n s t a l l a t i o n
4. Disassembly and Reassembly
5. Tro u b l e s h o o t i n h
5. Exploded Views and Parts List
6. Block Diagrams
7. PCB Diagrams
8. Wiring Diagrams
9. Schematic Diagrams
ROOM AIR CONDITIONER
INDOOR
AQ07A1AE
AQ07A2AE
AQ07B1AE
AQ07B2AE
OUTDOOR
UQ07A1AE
UQ07A2AE
UQ07B1AE
UQ07B2AE
Vue de la page 0
1 2 3 4 5 6 ... 46 47

Résumé du contenu

Page 1 - ROOM AIR CONDITIONER

SERVICEManualCONTENTSAIR CONDITIONER1. Pre c a u t i o n s2. Product Specifications3. Operating Instructions and I n s t a l l a t i o n4. Disassembly

Page 2 - Code No. DB81-00009A(1)

Samsung Electronics3-43-2 Installation3-2-1 Selecting Area for Installation Select an area for installation that is suitableto the customer's ne

Page 3 - 1. Precautions

Operating Instructions and Installation3-5Samsung Electronics3-2-2 Installation diagram of indoor unit and outdoor unitA Indoor unit gas leak test ch

Page 4

Operating Instructions and Installation3-6Samsung Electronics3-2-2(a) Fixing the Installation Plate3-2-2(b) Purging the UnitInstallation plate245(Un

Page 5 - 2. Product Specifications

Operating Instructions and Installation3-7Samsung Electronics3-2-2(c) Connecting the Assembly Cable.3-2-2(d) Installing and Connecting the Indoor Un

Page 6 - 2-3 Dimensions

Operating Instructions and Installation3-8Samsung Electronics3-2-2(e) Outdoor unit installation1. Remove the cover-E parts.2. Firmly connect the ca

Page 7 - 3-1 Operating Instructions

Operating Instructions and Installation3-9Samsung Electronics3-2-2(f) Flare ModificationFlare modification procedure1 ) Cut the pipe using a pipe cut

Page 8

Operating Instructions and Installation3-10Samsung Electronics3-2-2(g) Air-Purge Procedure• Use the refrigerant of the outdoor unit to purge air insi

Page 9 - OFF TIMER

Operating Instructions and Installation3-11Samsung Electronics3-2-2(h) Refrigerant Refill• Refill an air-conditioner with refrigerant when refrigeran

Page 10 - 3-2 Installation

Operating Instructions and Installation3-12Samsung Electronics3-2-2(i) Refrigerant Adjustment3-2-2(j) Flare unt fixing torqueClass At installation

Page 11

Samsung Electronics3-133-2-2(k) "Pump down" Procedure• Pump down' shall be carried out when an evaporator is replaced or when the unit

Page 12 - 3-2-2(b) Purging the Unit

© Samsung Electronics Co., Ltd. DEC 1998.Printed in Korea.Code No. DB81-00009A(1)

Page 13

4-1Sansung Electronics4. Disassembly and Reassembly4-1 Indoor UnitStop operation of the air conditioner and remove the power cord before repairing the

Page 14 - Drain Plug

Disassembly and Reassembly4-2Sansung ElectronicsNo Parts Procedure Remark234Ass’y Tray Drain.Electrical Parts(Main PCB)Heat Exchanger1) Do “1”, above.

Page 15 - Outer diameter A(mm)

4-3Sansung ElectronicsNo Parts Procedure Remark5 Fan Motor andCross Fan1) Do “1” “2” ”3” “4”, above.2) Loosen the fixing three screws and separatethe

Page 16 - 3-2-2(g) Air-Purge Procedure

4-4Sansung Electronics4-2 Outdoor UnitNo Parts Procedure Remark1 Common Work 1) Loosen the fixing screw and separate thecover E-parts.2) Separate the

Page 17 - 3-2-2(h) Refrigerant Refill

Disassembly and Reassembly4-5Sansung ElectronicsNo Parts Procedure Remark2 Fan and Motor 1) Do “1”, above.2) Loosen fixing screwof the Guard-fan.3) Tu

Page 18

Disassembly and Reassembly4-6Sansung ElectronicsNo Parts Procedure Remark34Heat ExchangerCompressor1) Do “1”, above.2) Loosen four fixing screws of As

Page 19 - 3-Way Valve

Samsung Electronics5-11 ) Is the voltage of the power corre c t ?The input voltage shall be rating voltage ±10%.The airconditioner may not operate pro

Page 20 - 4. Disassembly and Reassembly

Samsung Electronics5-25-2 Fault Diagnosis by Symptom5-2-1 No Power (completely dead)-Initial diagnosis1) Checklist :(1) Is input voltage normal? (the

Page 21 - Disassembly and Reassembly

Samsung Electronics5-35-2-2 When the Indoor Unit Fan Does Not Operate. (Initial Diagnosis)1) Checklist :(1) Is the indoor unit fan motor properly con

Page 22

5-4Samsung Electronics5-2-3 When the Outdoor Unit Does Not Operate. (Initial Diagnosis)1 ) Checklist :(1) Is input voltage normal?(rating voltage ±10%

Page 23 - 4-2 Outdoor Unit

1 . Warning: Prior to re p a i r, disconnect thepower cord from the circuit bre a k e r.2 . Use proper parts: Use only exact re p l a c e-ment parts

Page 24

Samsung Electronics5-5Troubleshooting5-2-4 When the UP/DOWN Louver Moter Does Not Operate. (Initial Diagnosis)1) Checklist :(1) Is input voltage norm

Page 25

Samsung Electronics5-65-2-6 If Operation By Remote Control Unit Is Impossible. (Initial Diagnosis)1) Troubleshooting pro c e d u reTroubleshootingRem

Page 26 - 5. Troubleshooting

Samsung Electronics5-75-3 PCB Inspection5-3-1 Cautions for Part Replacement5-3-2 ProcedureThe parts should be replaced in the following pro c e d u re

Page 27

Samsung Electronics5-85-3-3 Detailed ProcedureTroubleshootingNo.123456MalfunctionPull out the power plug from theAC terminal and confirm the fuseon th

Page 28 - Troubleshooting

Sansung Electronics5-95-4 Fault Diagnosis of Major PartsPartsTemp.SensorHeat ex. SensorIndoor Fan MotorOutdoor Fan MotorStepping Motor(UP/DOWN swing m

Page 29

6-1Samsung Electronics6. Exploded Views and Parts List6-1 Indoor Unit

Page 30

Samsung Electronics6-2Exploded Views and Parts List Parts ListNo.11-12345677-17-2891011121314151617181920212223CODE NODB64-10162ADB64-00001ADB64-70098

Page 31 - Samsung Electronics

6-3Samsung Electronics6-2 Outdoor Unit18-11818-2 18-3

Page 32 - 5-3 PCB Inspection

6-4Samsung ElectronicsExploded Views and Parts List Parts List No.123456788-18-299-110111213141516171818-118-2192020-120-222232425CODE NODB63-30168ADB

Page 33 - 5-3-3 Detailed Procedure

6-5Samsung Electronics6-3 Remote Control & PCB Box6-3-2 PCB Box Parts ListNo12345CODE NODB61-10151ADB93-10577ADB93-DB32-10008EDB26-10063BDB39-1006

Page 34 - Sansung Electronics

1-2Samsung ElectronicsM E M O

Page 35 - 6-1 Indoor Unit

7-1Samsung Electronics7. Block Diagrams7-1 Refrigerating Cycle Block DiagramINDOOR UNITOUTDOOR UNITHeatexchanger(Evaporator)Gas side3-way valve2-way v

Page 36 - Exploded Views and Parts List

8-1Samsung Electronics8. PCB Diagrams8-1 Main PCB(DB93-10576A) : AQ07A1AE, AQ07B1AE(DB93-10556A) : AQ07A2AE, AQ07B2AE

Page 37 - 6-2 Outdoor Unit

Samsung Electronics8-2PCB Diagrams Parts ListNo. CODE NO Description SpecificationQ’TYAQ07A1AE AQ07A2AE AQ07B1AE AQ07B2AE!!!!!!

Page 38

8-3Samsung Electronics8-2 ASS’Y DISPLAY & MODULE PCB : DB93-10619B Parts ListNo12345678910111213141316ACODE NODB41-10204B0601-0013330601-001059060

Page 39 - 6-3-2 PCB Box

Samsung Electronics9-19. Wiring Diagrams9-1 Indoor Unit

Page 40 - 7. Block Diagrams

9-2Samsung Electronics9-2 Outdoor UnitMODEL UQ07B1AE/UQ07B2AE/UQ07A1AE/UQ07A2AECAPACITOR 1.5/25uF 450VAC US07**AE

Page 41 - 8. PCB Diagrams

U P D A TE LOG SHEETApplication date Page Part# Note(Cause & Solution) S/Bulletin#Use this page to keep any special servicing information. (Servic

Page 42 - PCB Diagrams

Samsung Electronics10-110. Schematic Diagrams10-1 Indoor Unit

Page 43

Samsung Electronics2-12. Product Specifications2-1 TableModelItemPower SourceCapacity KWBTU/hAir circulation (High) m2/minMoisture removal (High) Lit

Page 44 - 9. Wiring Diagrams

2-2Samsung Electronics2-3 Dimensions2-3-1 Indoor Unit2-3-2 Outdoor Unit (Front view)745 177(Remote control)(Rear view)(Front view)(Rear view)235492506

Page 45 - 9-2 Outdoor Unit

Samsung Electronics3-13. Operating Instructions and Installation3-1 Operating InstructionsNO123456789101112131415NAMED OF KEYMODE(UP)(DOWN)TURBOOFFON

Page 46 - U P D A TE LOG SHEET

Samsung Electronics3-2Operating Instructions and Installation1. A U TO MODE : In this mode, operationmode(COOL, HEAT) is selected automati-cally by t

Page 47 - 10. Schematic Diagrams

Samsung Electronics3-38 . C O M P U L S O RY O P E R ATION : For operating the air conditioner withoutthe remote contro l l e r.* A U TO : The opera

Commentaires sur ces manuels

Pas de commentaire