Samsung HH175ECM Manuel d'installation

Naviguer en ligne ou télécharger Manuel d'installation pour Climatiseurs à système divisé Samsung HH175ECM. Samsung HH175ECM Installation manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 30
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
E§§HNIKA
INSTALLATION MANUAL
MANUAL DE INSTALACIÓN
MANUEL D’INSTALLATION
MANUALE D’INSTALLZIONE
MANUAL DE INSTALAÇÃO
INSTALLATIONS-HANDBUCH
E°XEIPI¢IO E°KATA™TA™H™
àçëíêìäñàü èé ìëíÄçéÇäÖ
Duct-type Air Conditioner (Cool & Heat)
Aire acondicionador Tipo Canal (Enfriamiento & Calefacción)
Climatiseur de type Conduit (Refroidissement et Chauffage)
Ar Condicionado Tipo Conduto (Refrigeração e Aquecimento)
Climatiseur de type Conduit (Refroidissement et Chauffage)
Ventiltype Klimaanlage (Kühlen und Wärmen)
KÏÈÌ·ÙÈÛÙÈÎfi T‡Ô˘ AÂÚ·ÁˆÁÔ‡ (æ‡Í˘ Î·È £¤ÚÌ·ÓÛ˘)
ÇÓÁ‰Û¯Ì˚È äÓ̉ˈËÓÌÂ íÛ·ÌÓ„Ó íËÔ‡ (éı·ʉÂÌËÂ Ë é·Ó„‚)
E S F I P D G R DB98-08778A(3)
HH105ECM
HH140ECM
HH175ECM
HH175EZM
RUSSIAN
ENGLISH
ESPAÑOL
FRANÇAIS
ITALIANO
PORTUGUÊS
DEUTSCH
Vue de la page 0
1 2 3 4 5 6 ... 29 30

Résumé du contenu

Page 1 - HH175EZM

E§§HNIKAINSTALLATION MANUALMANUAL DE INSTALACIÓNMANUEL D’INSTALLATIONMANUALE D’INSTALLZIONEMANUAL DE INSTALAÇÃOINSTALLATIONS-HANDBUCHE°XEIPI¢IO E°KATA

Page 2 - Contents

Cutting/Flaring the pipesE-10Connect the pipe within 50m and cutting pieces will not be gone into the pipe as being clean to pipe section.Make sure th

Page 3

ENGLISHE-11Performing leak testsInsulationBefore completing the installation (insulation of the hose and piping), you must check that there are no gas

Page 4 - Preparation for installation

Drain hose installationCare must be taken when installing the drain hose for the indoor unit toensure that any condensate water is correctly drained o

Page 5

Testing the drainagePrepare a little water about 5 liters.Pour water into the base pan in the indoor unit as shown in figure.1Confirm that the water f

Page 6 - Drawing of the indoor unit

E-14Connecting the connection cord The indoor unit is powered from the outdoor unit via the connection cord.Remove the screw on the electrical compone

Page 7 - Ceiling support

ENGLISHE-151(L)2(N)1(L)2(N)Vc Vc Vw Vw FA FB F1 F2 V1 V2Receiver & Display Unit(Optional)Transmitter(Optional)CentralizedController(Optional)Float

Page 8 - Purging the unit

E-16Group control installationK9K10K11K12K9K10K11K12The group control can control 16 rooms(64 indoor units/standard) witha wired controller. When a wh

Page 9

ENGLISHE-17Before installing the indoor unit, assign an address to the indoor unitaccording to the air conditioning system plan.1The address of the in

Page 10 - Cutting/Flaring the pipes

E-18Assigning address to indoor unit (Cont.)The MAIN address is for communication between the indoor unit and the outdoorunit. Therefore, you must set

Page 11 - Insulation

ENGLISHE-19Additional functionsCompensation for lost temperature in heating operation◆ Reduces the difference between an actual room temperature and a

Page 12 - Cable-Tie

E-2 Parts list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28OOOOPPPPTTTTIIIIOOOONNNNAAAALLLLAAAACCCCC

Page 13 - Testing the drainage

Increasing fan speedE-20The vertical axis is the external static pressure(mmAq) while the horizontalaxis represents the AIR FLOW(m3/min).1The characte

Page 14 - Specifications

Air filter installation (Optional)ENGLISHE-21Remove the air inlet duct flange.1Attach the air filter kit to the air inlet side of indoor unit.2To cle

Page 15 - Indoor Unit

Drain pump installation (Optional)E-22Open the side of indoor unit.Screw the drain pump with two screws.12Connect the drain hose to the drain socket.3

Page 16 - Group control installation

ENGLISHE-23K1 K2 K3 K4SW03Drain pumpFloat switchCable-tieIndoor unitDrain pump hose portDrain hoseInsulationMust fit tightly against body without any

Page 17 - RMC(SW01) rotary switches

E-24TroubleshootingDetection of errors◆ If an error occurs during the operation, an LED flickers and the operation is stopped except the LED.◆ If you

Page 18 - SW02 MAIN SW01 RMC

ENGLISHE-25LED Display● On Flickering X Off◆If you turn off the air conditioner when the LED is flickering, the LED is also turned off.◆If y

Page 19 - K5 K6 K7 K8

The order of priority : EA → Eb → ox → qx → rx → tx → Ux → vx → Eo - In case that the same error displays from multi-indoor units, the one having t

Page 20 - K1 K2 K3 K4

Parts list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28OOOOPPPPTTTTIIIIOOOONNNNAAAALLLLAAAACCCCCCCCEEEESSSSSSSSOOOORRRRI

Page 21 - Accessories

E-28Receiver & Display Unit AccessoriesReceiver &display unit 1STS 2S-2x10tapped screw 42S-4x12tapped screw2Owner’sinstructions1Wire kit (

Page 22

ENGLISHE-29Centralized Controller AccessoriesCentralizedcontroller 1Cable-tie 2Cable clamp5M4x16 tappedscrew7Transmitter AccessoriesTransmitter com-m

Page 23

E-3 Preparation for installation . . . . . . . . . . . . . . . . . . . . . 4 Deciding on where to install the indoor unit . . . . . . . . 5 Ind

Page 24 - Troubleshooting

THIS AIR CONDITIONER IS MANUFACTURED BY:ESTE AIRE ACONDICIONADO HA SIDO FABRICADO POR:CE CLIMATISEUR EST FABRIQUE PAR:QUESTO CONDIZIONATORE D’ARIA È P

Page 25 - LED Display

E-4Preparation for installationWhen deciding on the location of the air conditioner with the owner,the following restrictions must be taken into accou

Page 26 - Troubleshooting (Cont.)

ENGLISHE-5Deciding on where to install the indoor unit5mm5mmYou must have 5mm or more space between the ceiling and the bottom of indoor unit.Otherwis

Page 27

Deciding on where to install the indoor unit (Cont.)E-6Unit : mmDrawing of the indoor unit◆ The inside of ( ) is for HH105/140ECM models.◆ The outsid

Page 28 - Parts list

Indoor unit installationENGLISHE-71Place the pattern sheet on the ceiling at the spot where you want toinstall the indoor unit.2Insert bolt anchors. U

Page 29 - Transmitter Accessories

E-8Purging the unitOn delivery, the indoor unit is loaded with an inert nitrogen gas. All this gas must therefore be purged before connecting the asse

Page 30

ENGLISHE-9Connecting the indoor unit assembly pipingDrain hose connection portLiquid refrigerantportDrain pump hoseconnection portGas refrigerant port