Temperature and Humidity Ranges
The following table indicates the temperature and humidity ranges within which the air conditioner can be used.
If the air conditioner is used at... Then...
High temperatures
The automatic protection feature may be triggered and the air conditioner stopped.
Mode Outdoor Temperature Indoor Temperature Indoor Humidity
Heating 0°C to 24°C approx. 27°C or less -
Cooling 21°C to 43°C approx. 18°C to 32°C approx. 80% or less
Drying 18°C to 43°C approx. 18°C to 32°C approx. -
If the heating operation is used at below 0°C(outdoor temperature), it does not heat at its full capacity.
If the cooling operation is used at over 33°C(indoor temperature), it does not cool at its full capacity.
Low temperatures
A water leak or some other malfunction may occur if the heat exchanger freezes.
High humidity levels
Water may condense on and drip from the surface of the indoor unit if it is used for long periods.