Slide 35
Caution: There are high voltages
present on the printed circuit board
+12VDC
+5VDC
There are high voltages present on
the larger heat sink mounted to the
board.
Slide 36
Freezer
drain tube
Drain
slots
Vent
holes
Refrigerator
drain tube
Each evaporator has it’s own drain
hose. Make sure that these hoses are
installed with the slots near the
bottom.
Slide 37
Harmonic
Balancer
Compressor component routing.
The rubber grommet on the
discharge tube is for noise
reduction.
The compressor relay cover pries
out and down from the compressor
housing.
The compressor uses a PTC starting
device.
The compressor harness and PTC
can be removed either separately or
as an assembly.