Fixing the indoor unit in place
Insulation
Pipes
Perform the following work on the area where gas leak test was done priory.
After checking for gas leaks in the system, insulate the pipe, hose and cables.
Then place the indoor unit on the installation plate.
1. To minimise condensation problems, wrap foam insulation (as shown in the
gure) on a part without insulation on the end of the pipes.
2. Wind the pipe, assembly cable and drain hose with vinyl tape.
3. Place the bundle (the pipe, assembly cable and drain hose) in the lower part
of the indoor unit carefully so it does not project from the rear of the indoor
unit.
4. Hook the indoor unit to the installation plate and move the unit to the right
and left until it is securely in place.
5. Wrap the rest of the pipe with vinyl tape.
6. Attach the pipe to the wall using clamps (optional).
Installation
plate
Connecting wires
Connecting
pipes
Vinyl tape
Drain hose
• Makesurepipedoesnotmovewhenyouinstalltheindooruniton
an installation plate.
English-42