Samsung SRP-275 Manuel de l'opérateur Page 101

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 110
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 100
5-110 5-111
EOT
[Name] Inquire EOT status
[Format] ASCII EOT
Hex 04
Decimal 4
[Range] ------
[Default] ------
[Description] This command is effective only when using an interface capable of
bi-directional data communications.
When this command is received, the printer sends the EOT status in real time
to the host (not taking it from the reception buffer, but executing it immediately
upon reception from the host). Bi-directional parallel interfaces enter a
"data present" state.
Bit Contents
Status
7
6
5
4
3
2
1
0
Fixed at "1"
Paper end
Paper near-end
Fixed at "0"
"0"
Paper
No error
"1"
-
No paper
Error
-
CONTROL COMMANDS LIST
CHAPTER 5
ENQ
[Name] Inquire ENQ status
[Format] ASCII ENQ
Hex 05
Decimal 5
[Range] - - -- - -
[Default] ------
[Description] This command is effective only when using an interface capable of
bi-directional data communications.
When this command is received, the printer sends the ENQ status in real time
to the host (not taking it from the reception buffer, but executing it immediately
upon reception from the host). Bi-directional parallel interfaces enter a
"data present" state.
Bit Contents
Status
7
6
5
4
3
2
1
0
Drawer kick-out connector status
Buffer overflow
Reception Buffer Empty
Fixed at "0"
Paper end
Mechanical error
Framing error
Parity error
"0"
OPEN
No error
Has Data
Paper
No error
No error
No error
"1"
CLOSE
Overflow
Empty
-
No paper
Error
Error
Error