4 way cassette S
X Ratings shown are net capacities.
X Capacities are based on following conditions;
- Equivalent refrigerant piping length : 5m / Level difference : 0m.
;
Note
(1) Cooling
Indoor
Temperature(°C)
Outdoor Temperature (°C, DB)
-15 21 35 43 50
WB DB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14 20
11.71 9.37 2.14 13.39 10.71 3.25 11.62 9.30 3.25 10.41 8.33 4.74 7.16 5.73 4.09
16 22
12.00 9.60 2.19 13.72 10.97 3.33 11.91 9.53 3.33 10.67 8.54 4.86 7.33 5.87 4.19
18 25
12.30 9.84 2.24 14.05 11.24 3.42 12.20 9.76 3.42 10.93 8.74 4.98 7.52 6.01 4.29
19 27
12.60 10.08 2.30 14.40 11.52 3.50 12.50 10.00 3.50 11.20 8.96 5.10 7.70 6.16 4.40
22 30
12.90 10.32 2.36 14.75 11.80 3.58 12.80 10.24 3.58 11.47 9.18 5.22 7.88 6.31 4.51
24 32
13.21 10.57 2.41 15.10 12.08 3.67 13.11 10.49 3.67 11.74 9.40 5.35 8.07 6.46 4.61
(2) Heating
Indoor
Temperature(°C)
Outdoor Temperature (°C, DB)
-20 -10 7 24
DB TC PI TC PI TC PI TC PI
16
11.53 5.41 12.24 5.20 14.28 3.66 17.65 4.18
18
11.41 5.35 12.12 5.15 14.14 3.63 17.47 4.14
20
11.30 5.30 12.00 5.10 14.00 3.59 17.30 4.10
21
11.19 5.25 11.88 5.05 13.86 3.55 17.13 4.06
22
11.08 5.19 11.76 5.00 13.72 3.52 16.96 4.02
24
10.96 5.14 11.64 4.95 13.58 3.48 16.79 3.98
TC(Total Capacity, kW), SHC(Sensible Heat Capacity, kW), PI(Power Input, kW)
TC(Total Capacity, kW), PI(Power Input, kW)
14) RC140DHXEB + NS1404DXEA
(1) Cooling
Indoor
Temperature(°C)
Outdoor Temperature (°C, DB)
-15 21 35 43 50
WB DB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14 20
13.00 10.40 3.52 14.88 11.91 4.42 13.02 10.41 4.05 12.69 10.15 5.95 8.37 6.69 3.63
16 22
13.32 10.66 3.61 15.25 12.20 4.53 13.34 10.67 4.15 13.00 10.40 6.10 8.57 6.86 3.72
18 25
13.65 10.92 3.70 15.62 12.50 4.64 13.66 10.93 4.26 13.32 10.66 6.25 8.78 7.03 3.81
19 27
13.98 11.19 3.79 16.01 12.81 4.75 14.00 11.20 4.36 13.65 10.92 6.40 9.00 7.20 3.90
22 30
14.32 11.45 3.88 16.39 13.11 4.87 14.34 11.47 4.46 13.98 11.18 6.56 9.22 7.37 3.99
24 32
14.66 11.73 3.97 16.78 13.43 4.98 14.68 11.74 4.57 14.31 11.45 6.71 9.44 7.55 4.09
(2) Heating
Indoor
Temperature(°C)
Outdoor Temperature (°C, DB)
-20 -10 7 24
DB TC PI TC PI TC PI TC PI
16
12.24 6.32 13.58 6.13 16.32 4.52 19.48 4.49
18
12.12 6.26 13.45 6.07 16.16 4.47 19.29 4.44
20
12.00 6.20 13.31 6.01 16.00 4.43 19.10 4.40
21
11.88 6.14 13.18 5.95 15.84 4.39 18.91 4.36
22
11.76 6.08 13.05 5.89 15.68 4.34 18.72 4.31
24
11.64 6.02 12.92 5.83 15.52 4.30 18.53 4.27
TC(Total Capacity, kW), SHC(Sensible Heat Capacity, kW), PI(Power Input, kW)
TC(Total Capacity, kW), PI(Power Input, kW)
3-2. Capacity tables
13) RC125PHXGA + NS1254PXEA